Last News
D-ONE Diving Helmet
D-ONE Diving Helmet
22/11/2019 0

HAAS VM3, the new entry!
HAAS VM3, the new entry!
22/03/2019 0

HAAS UMC750
HAAS UMC750
22/02/2019 0

Potting and Encapsulation services
Potting and Encapsulation services
08/03/2016 0

NEW Subspec HVQD Connector
NEW Subspec HVQD Connector
04/03/2016 0

Constant climate chambers KBF 115

Posted by Subspec 23/10/2015 0 Comment(s) Commercial,

Important characteristics

  • Temperature range: 0 °C to 70 °C
  • Humidity range: 10 % to 80 % RH
  • APT.line™ preheating chamber technology
  • Humidity regulation with capacitative humidity sensor and vapor humidification
  • Controller with time-segment programming
  • Tightly-sealed inner door made of tempered safety glass
  • 2 stainless steel racks
  • Access port with silicone plug, 30 mm, left
  • Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
  • Computer interface: Ethernet
  • Door heating

Designation KBF115-230V KBF115UL-240V
Option model Standard Standard
Order number 9020-0267 9020-0268
Performance Data Temperature
Temperature range [°C] 0…70 0…70
Temperature uniformity at 40 °C [± K] 0.2 0.2
Temperature fluctuation [± K] 0.1 0.1
Max. heat compensation at 40 °C [W] 200 200
Recovery time after 30 seconds door open at 25 °C and 60 % RH [min] 15 15
Recovery time after 30 seconds door open at 40 °C and 75 % RH [min] 8 8
Performance Data Climate
Temperature range [°C] 10…70 10…70
Temperature uniformity at 25 °C and 60 % RH [± K] 0.2 0.2
Temperature uniformity at 40 °C and 75 % RH [± K] 0.2 0.2
Temperature fluctuation at 25 °C and 60 % RH [± K] 0.1 0.1
Temperature fluctuation at 40 °C and 75 % RH [± K] 0.1 0.1
Humidity range [% RH] 10…80 10…80
Humidity fluctuation at 25 °C and 60 % RH ≤2 ± % RH ≤2 ± % RH
Humidity fluctuation at 40 °C and 75 % RH ≤2 ± % RH ≤2 ± % RH
Electrical data
Rated Voltage [V] 200…230 200…240
Power frequency [Hz] 50/60 50/60
Nominal power [kW] 2 2
Phase (Nominal voltage) 1~ 1~
Measures
Interior volume [L] 102 102
Net weight of the unit (empty) [kg] 129 129
Load per rack [kg] 30 30
Measures - Doors
Inner doors 1 1
Unit doors 1 1
Measures - Internal Dimensions
Width [mm] 600 600
Height [mm] 483 483
Depth [mm] 351 351
Measures - Outer dimensions
Width net [mm] 880 880
Height net [mm] 1050 1050
Depth net [mm] 650 650
Wall clearance back [mm] 100 100
Wall clearance sidewise [mm] 100 100
Environment-specific data
Energy consumption at 40 °C and 75 % RH 470 Wh/h 470 Wh/h
Sound-pressure level [dB(A)] 52 52
Loading...